SCX sampler UOP reference design and manufacturing technology, applicable dry oil, Chemical plant inside the right conditions of various media, particularly toxic, flammable, explosive and other hazardous, Low-pressure gas, liquid medium without leakage sampling. Strong samples authenticity, accuracy, no residue, residue gas emissions.Effectively prevent toxic and harmful media in the operation of the injury. Meanwhile, it will not pollute the environment, avoiding flammable and explosive liquid in the sample might have dangerous incidents.Comply with national environmental and fire, explosion norms.
SCX.SCX sampler in the domestic petrochemical technology devices, such as residue hydrotreating, RFCC, gas fractionation devices used, was unanimously acclaimed. I produced the SCX - sampler for the main-line SCXL type sampler and SCXM-closed sampler two. Users can request a different selection process.The sampler are the main materials or 1Cr18Ni9Ti OCrl8Ni9Ti appearance generous, gorgeous.
1、S1, SCXL-Online sampler ■ structural features
SCX.SCX sampler in the domestic petrochemical technology devices, such as residue hydrotreating, RFCC, gas fractionation devices used, was unanimously acclaimed. I produced the SCX - sampler for the main-line SCXL type sampler and SCXM-closed sampler two categories. Users can request a different selection process.The sampler are the main materials or 1Cr18Ni9Ti OCrl8Ni9Ti appearance generous, gorgeous.

■ type, scope and methods of use
① SCXL-IA liquid-line sampler
■ scope : the sampler applicable to the various viscosity, no strong corrosive liquid sampling.
Temperature : -20~200 ° C, pressure : 0~6.4Mpa
■ Use : (1) storage-sampling bottle at the mouth of the bottle of fluid pipe :
(2) an anti-clockwise, slowly rotating sampler to handle population outflow of liquid dielectric date :
(3) adopt adequate samples immediately after the clockwise direction of rotation sampler to handle all rotary screw-up.
■ models and parameters : 
② SCXL-IB liquid-line sampler
■ scope : the sampler applicable to the various viscosity, the non-corrosive liquid sampling. Yi also can be used as part of the condensate blocking emptying valves, check valves. Temperature : -20~425 ° C, pressure : 0~6.4Mpa
■ Use :
(1) storage at the mouth of the bottle-like sampler of fluid pipe.
(2) an anti-clockwise rotation slowly sampler to handle the population outflow from liquid medium to date.
(3) to be adopted after the samples immediately clockwise direction of rotation of the sampling device to handle all rotary screw-up.
■ models and parameters 
③ SCKl-IC liquid-line sampler
■ scope : the sampler applicable to the various viscosity, temperature-corrosive, flammable liquid sampling. Temperature : -20~425 ° C, pressure : 0~6.4Mpa
■ Use :
(1) first sampler fluid cooler mouth of access coolant;
(2) storage at the mouth of the bottle-like sampler of fluid pipe;
(3) an anti-clockwise rotation slowly sampler to handle the population outflow from liquid medium;
(4) to be adopted after the samples immediately clockwise direction of rotation of the sampling device to handle all rotary screw-up.
④ SCXL- II gas-line sampler
■ scope : not applicable to particles, condensation and crystallization of the sample gas media.
Temperature : -20-425 ° C, pressure : 0-6.4Mpa
■ Use :
(1) first receptacles airbag gas production sampler inserted to take over the gas production joints
(2) by an anti-clockwise rotation slowly sampler to handle media access storage airbags, adopt adequate sample, immediately clockwise direction of rotation sampler to screw up all the swing.
(3) sealed storage airbags intake manifold, then take on the joints locking up mobile sets, taken automatically take over the gas and gas production joint undocking.
■ models and parameters :
2, SCXM-confined sampler
SCXM-confined sampler, mainly by the box, sampling bottles, cans buffer, fast change hands round, the pressure gauges, valves, Seals and flange components.
■ structural features
As the sampling bottles and technology between the use of trade off with a fast round of connecting, it is simple, rapid and convenient.
■ scope of technical parameters
① SCXM-IA liquid closed sampler
■ scope : applicable to various toxic, hazardous, flammable, explosive and other liquid sampling.
■ technical parameters : Sample Temperature : -20-60 ° C, the design pressure : 0~10.0Mpa sampling volume : 100ml
注:N1、N2、N3管口为DN15 PN1.6~10.0Note : N1, N2, N3 pipe to DN15 PN1.6~10.0
② SCXM-IB liquid closed sampler
■ scope : applicable to various toxic, hazardous, flammable, explosive and other liquid sampling.
■ technical parameters : Sample Temperature : -20~400 ℃, the design pressure : 0~10.0Mpa sampling volume : 100ml
注:N1、N2、N3管口为DN15 PN1.6~10.0Note : N1, N2, N3 pipe to DN15 PN1.6~10.0 N4、N5、N6管口为DN20 PN1.6N4, N5, N6 pipe to DN20 PN1.6 ③ SCXM-IIA Gas closed sampler
■ scope : applicable to various toxic, hazardous, flammable, explosive gases and other media sampling.
■ technical parameters : temperature : -20~50 ℃, the design pressure : 0~10.0Mpa sampling volume : 200ml~500m1
注:N1、N2、N3、N4管口为DN15 PN1.6~10.0Note : N1, N2, N3, N4 pipe to DN15 PN1.6~10.0 ④ SCXM-IIB Gas closed sampler
■ scope : applicable to various toxic, hazardous, flammable, explosive gases and other media sampling.
■ technical parameters : Sample Temperature : -20~400 ℃, the design pressure : 0~10.0MPa sampling volume : 200ml a 500m1
注:N1、N2、N3、N4管口为DN15 PN1.6~10.0Note : N1, N2, N3, N4 pipe to DN15 PN1.6~10.0 N5、N6、N7管口为DN20 PN1.6N5, N6, N7 pipe to DN20 PN1.6 Notes orders 1, ordering Please specify details sampler models, media names, pressure and temperature. 2, please indicate the surface flange connecting standards.